Welcome to the guide on Fire Angel Carbon Monoxide Alarms, essential devices designed to detect deadly CO gas. The CO-9B and CO-9D models offer reliable protection, meeting EN 50291 standards with features like LED indicators and a 7-year lifespan for continuous safety.
1.1 Overview of the Fire Angel CO-9B and CO-9D Models
The Fire Angel CO-9B and CO-9D are advanced carbon monoxide detectors designed to provide reliable protection against CO gas. Both models are lightweight, with the CO-9B weighing 255 grams and the CO-9D weighing 120 grams, including batteries. They are certified to EN 50291-1:2010 and EN 50291-2:2010 standards, ensuring compliance with European safety regulations. The CO-9B features a compact design with LED indicators for power and alarm status, while the CO-9D includes a digital display and voice alerts for enhanced functionality. Both models are designed for continuous monitoring of carbon monoxide levels, offering peace of mind for homeowners.
Installation Instructions for Fire Angel CO Alarms
Ensure the alarm is installed by a competent person, placed at least 1-3 meters horizontally from fuel-burning appliances, and mounted on walls or ceilings as instructed.
2.1 Where to Position the Alarm
Position the Fire Angel CO alarm at least 1-3 meters horizontally from fuel-burning appliances. Install on walls or ceilings, avoiding areas near windows or doors. Ensure it’s not blocked by curtains or furniture. For rooms with partitions, place the alarm on the same side as the potential CO source. Keep it at least 30cm away from any corner. Follow these guidelines to ensure optimal detection and safety in your home.
2.2 How to Activate the Alarm
To activate the Fire Angel CO alarm, attach the base plate to the unit. Wait up to 1 minute for the green LED to flash, confirming activation. For models like the CO-9D, press the Test/Mode button once per week to test the power pack, sounder, and circuitry. Ensure the alarm is properly installed and powered to guarantee accurate CO detection. Activation ensures the device is ready to monitor for dangerous CO levels in your home.
Testing and Maintenance of the Fire Angel CO Alarm
Regular testing is crucial. Press the Test button monthly to ensure the alarm functions properly. The alarm will sound, and the red LED will flash twice every 40 seconds. Clean the unit regularly and replace batteries annually to maintain effectiveness.
3.1 Monthly Testing Procedures
To ensure your Fire Angel CO alarm functions correctly, perform monthly tests. Press and hold the Test button until the alarm sounds. The red LED will flash twice every 40 seconds, confirming the alarm is operational. This test verifies the sensor, sounder, and circuitry are working. For models with a hush button, pressing it will silence the alarm temporarily. After testing, ensure the alarm reactivates properly. Regular testing helps maintain reliability and ensures your safety from carbon monoxide threats. Always follow the manufacturer’s instructions for accurate results;
3.2 Regular Maintenance Tips
Regular maintenance ensures your Fire Angel CO alarm remains effective. Vacuum the sensor with a soft brush to remove dust and debris. Check the expiration date on the alarm, typically 7 years from manufacture. Replace the battery (if applicable) as instructed. Avoid exposing the alarm to cleaning chemicals or extreme temperatures. Test the alarm monthly to confirm proper function. Inspect the device for physical damage and ensure it’s securely mounted. Follow these tips to maintain optimal performance and reliability of your Fire Angel carbon monoxide alarm.
Understanding the Alarm Features
The Fire Angel CO-9B features LED indicators for power and alarm status, ensuring easy monitoring. Compact and lightweight, it offers reliable detection with tamper-proof design and EN certification.
4.1 LED Indicators for Status Monitoring
The Fire Angel CO-9B boasts advanced LED indicators for real-time status updates. A green LED signifies normal operation, while a red LED flashes during an alarm. Additionally, a yellow LED indicates a fault, ensuring users are informed of any issues promptly. These visual cues provide straightforward monitoring, making it easy to assess the alarm’s status without confusion. The LED system is designed for reliability, offering clear alerts for accurate response to potential dangers;
Certifications and Compliance Standards
Fire Angel CO alarms comply with EN 50291-1:2010 and EN 50291-2:2010 standards, ensuring reliability and safety in detecting carbon monoxide effectively.
5.1 EN 50291-1:2010 and EN 50291-2:2010 Compliance
Fire Angel CO alarms are certified to EN 50291-1:2010 and EN 50291-2:2010 standards, ensuring they meet rigorous European safety requirements for carbon monoxide detection. These standards mandate specific response times and sensitivity levels to guarantee accurate detection of CO levels, providing reliable protection for users. Compliance ensures the alarms perform consistently under various conditions, adhering to strict safety protocols and offering peace of mind for homeowners and businesses.
Troubleshooting Common Issues
Address common issues like false alarms or faulty detection by referring to the user manual. Check for obstruction, test functionality, and ensure proper installation for optimal performance.
6.1 Resolving False Alarms
False alarms on Fire Angel CO alarms can occur due to dust, cooking fumes, or steam. Press the hush button to temporarily silence the alarm. Ensure the sensor is clean and free from obstructions. Relocate the alarm if it’s near potential sources of interference. If false alarms persist, check for proper installation and ensure the device is functioning correctly. Contact customer support if issues remain unresolved for further assistance or replacement options.
Warranty and Replacement Information
The Fire Angel CO-9B and CO-9D alarms come with a 7-year warranty. Replacements are covered under the original warranty period, ensuring continuous protection and peace of mind for users.
7.1 Warranty Period and Terms
The Fire Angel CO-9B and CO-9D alarms are backed by a 7-year manufacturer’s warranty. This warranty covers defects in materials and workmanship for the duration of the period. If a fault is detected, contact Fire Angel customer support for a replacement, which will honor the original purchase warranty. The warranty does not cover damage caused by misuse or tampering. Regular testing and maintenance ensure the device functions optimally under warranty conditions. Always refer to the user manual for detailed warranty terms and conditions.
Operating Conditions
The Fire Angel CO alarms operate effectively in temperatures between 10°C to 40°C (14°F to 104°F) and humidity levels of 30% to 90% RH, weighing 90 grams.
8.1 Temperature and Humidity Range
The Fire Angel Carbon Monoxide Alarms are designed to function optimally within specific environmental conditions. The temperature range for operation is 10°C to 40°C (14°F to 104°F), ensuring performance across various climates. Additionally, the alarms are effective in humidity levels between 30% and 90% RH, making them suitable for different indoor environments. These specifications ensure reliable detection of carbon monoxide without interference from typical household humidity or temperature fluctuations, maintaining safety and efficiency in various settings.
Safety Precautions
Never cover the alarm or expose it to extreme conditions. Avoid tampering with the device. Ensure proper installation and regular testing to maintain functionality and safety.
9.1 Important Safety Notes for Installation and Use
Ensure the alarm is installed by a competent person following instructions. Do not tamper with the device or cover it. Avoid exposing the alarm to direct sunlight, humidity, or extreme temperatures. The alarm is not a smoke or combustible gas detector; install separate devices for those hazards. Keep the sensor clean and free from obstructions. Never test the alarm with actual carbon monoxide. If the alarm sounds, evacuate immediately and investigate the source. Regular testing ensures proper function, but it does not guarantee detection of all CO sources.